UJP PRAHA a.s.
Menu
  • Homepage
  • News
  • Products
  • Certification
  • References
  • Grant projects
  • About us
  • Download
  • Contacts
  • CS
Linkedin

Medical and laboratory technology

Medical and laboratory technology
Our product portfolio is based on the TERABALT radiotherapy cobalt unit, the TERASIX X-ray simulator designed for exact radiotherapy planning and the PlanW planning system.
Medical
technology
Development
and research
Nuclear
industry
Special
packaging files
Industrial
services

submenu

We have been involved in the development, production and certification of medical and laboratory devices according to ISO 13485 since 1996. In 2013, we expanded our specialization to include equipment for calibration laboratories. Our quality management system is certified to ISO 13485. Thanks to our many years of experience and expertise in the field, we produce high-quality medical devices contributing to the treatment of cancer and non-cancer diseases all over the world. We place great emphasis on the development and production of equipment specifically designed for radiotherapy. We are a member of the Association of Manufacturers and Suppliers of Medical Devices of the Czech Republic and we cooperate with the International Atomic Energy Agency (IAEA) with the aim of expanding access to our radiotherapy systems in low- and middle-income countries. Thanks to this cooperation, we can provide oncology care and positively influence the health of patients around the world.

Our portfolio includes:

Medical devices
Software
Laboratory equipment
Services

Medical devices

TERABALT

Radiotherapy set is manufactured in four modifications with a fully digitized steering system and rich accessory and accessories. The TERABALT radiation set is the representative of a new generation of megavolt cobalt radiotherapy. The source of radiation is the radionuclide of the cobalt 60 element. The technical design, design and efficiency of the assembly provides a guarantee of high utility value in clinical practice in the treatment of cancer.

TERASIX

X-ray simulator with unique VirtualBiemView technology is used to verify and prepare radiotherapy treatment. Radiation therapy with high irradiation demands currently requires a precise therapy plan to eliminate errors in the chosen radiotherapy procedure and to minimize the impact of healthy tissues on irradiation on the radiotherapy device. UJP PRAHA a.s. has therefore developed a fully electronically controlled TERASIX X-ray simulator for accurate planning, which meets all the requirements for accurate radiotherapy treatment.

PLANW

PlanW – Treatment Planning System for Radiotherapy (TPS) is specialized software supporting treatment plans calculation in external beam radiotherapy. It supports treatment plans calculation for radionuclide treatment units and also for linear accelerators, both X-ray and electron beams. It allows treatment plans calculation for combination of different types of radiation. The modern treatment techniques as IMRT and IMAT are also implemented. PlanW TPS is able to communicate with other systems (CT, NMR, PET, PACS, etc.) used in radiation therapy by DICOM 3 format. PlanW TPS is a network system with client-server architecture. The client can run simultaneously with server on one computer. The number of clients is unlimited.

TERAGIS

TERAGIS – Record and Verify System for Radiotherapy (RVS), is a programmable electrical medical system that is used to help prevent erroneous set-up of the TERABALT radiotherapy unit or TERASIX X-ray simulator and to record all treatment sessions. This is accomplished through verification of the set-up and preventing machine operation if the set-up does not match predetermined settings.

Software

PLANVERI

Independent Radiotherapy Dose Calculation Validation automatically performs an independent review and validation of the radiotherapy department's primary planning system's dose calculation algorithm for each patient plan.

Laboratory equipment

T100

T100 dosimetric irradiator is designed to generate quantified gamma radiation doses, in particular for the verification and calibration of dosimetric systems or for irradiation in chemical, material and biological research. The design is based on the Terabalt / Teragam therapeutic irradiator, the head of which forms the basic shielding body, while allowing the URZ to be moved to the working or shielded position. The cap is placed in a covered rack.

Services

In the field of medical technology, we also offer

  • disposal of medical technology including mandatory documentation
  • supplying resources to the healthcare facility
  • software development for healthcare facilities

Customer support

Medical and laboratory technology

Další galerie

Development and research
Nuclear industry
Special packaging files
Industrial services
Customer support
Terabalt
Terasix
PLANVERI
Tungsten materials Tungsten materials
Zirconium alloys
Special compounds
Titanium alloys Titanium alloys
Nickel alloys Nickel alloys
Packaging files type A
Packaging files type B (U)
Packaging files for neutron sources
Up
JuicyFolio

UJP PRAHA a.s. with registered office at Nad Kamínkou 1345, 156 00 Prague 5 - Zbraslav, data box ID: fw4gs5f,
Registered in the commercial register at the Municipal Court in Prague, section B, insert 2366, ID 601 93 247

© 2007–2023, UJP PRAHA a.s. – all rights reserved.

Cookies GDPR Created by intencio